IV. ANALYSIS: ANALYTICAL METHODS
IV-15
MATHEMATICAL SOLUTIONS (Continued)
Figure IV-5 shows the plotted solutions that can be used to determine the flow under a
concrete weir on a pervious foundation of finite depth using a partially penetrating cutoff.
FIGURE IV-5. IMPERVIOUS STRUCTURE WITH PARTIAL CUTOFF ON
LAYER OF FINITE DEPTH