The Cr–Cu–Ni rails laid in the corrosion-prone areas are presently being evaluated under field conditions. At the same time, samples from actual Cr–Cu–Ni, C–Mn and
Cu–Mo rails were evaluated specially for their crevice corrosion resistance using the standard ASTM G78 method.