Comparison results show that the structure of the three-phase transformer leads to bigger
volume when temperature rise is the design limitation and
smaller one when flux and current densities are constrained.
And when all the three specifications hit the limit, the
difference of volumes of single and three-phase transformer
is within 5%. One 20 kHz, 300V, 1 kW prototype system
has been built and verifies the analysis