For a product in a given container closure system, container size and fill, an appropriate approach for deriving the rate of water loss at the low relative humidity is to multiply the rate of water loss measured at an alternative relative humidity at the same temperature, by a water loss rate ratio shown in the table below.
A linear water loss rate at the alternative relative humidity over the storage period should be demonstrated.