We regards this test result as reference data.
Because some parts were temporary.
-Header Cap: Used LG part, t1.2mm, OD Φ17.6mm
-Slot width of header pipe: Less than 16.1mm.
It was so difficult to assemble condenser.
So production operator used the hammer at assembling.
Parts were deformed, and header pipe and tube might be scratched at that time. It might affect the parts strength.
R&D will test again after off-tooling part are completed.
R&D will not accept to test temporary parts in the future.