After mechanical testing, the fracture surfaces associated with
select tensile and impact specimens were studied using scanning
electron microscopy (SEM) (Oxford Instruments, Model 7718, England)
in order to better characterize the failure mechanisms and
damage morphology. A thin gold coating was deposited over the
composite failure surfaces to increase local electrical conductivity
and enhance the resolution of the SEM images