where Ron is the on-state resistance and Vt the voltage over the device during on-state
(threshold voltage). Also here the voltages and currents are measured at every sampling
instance during a simulation and hence the currents and voltages can be assumed to
be constant for each term in the sum calculation. To get the total conduction power
losses for all devices during one second the conduction energies for all switches has to be
summed up.