The system to consist of 2 identical air cooled piston type air compressors, fully automatically operated pressure control switches, check valves, pre-relieve and stop valves. Capacity to fulfill class requirements, but min. 25m3/h each compressor.
The system will be designed so that one or both compressors will start automatically based on pressure in air receivers.
2 starting air receivers according to the classification society’s rules, and engine manufacturer’s recommendations. Receiver will be equipped with charging valves, safety valves, drains, etc according to the Class requirements.
The builder will install an oil and water separator, in the airline from compressors to air vessels, with automatic drain.
Reducing system from starting air receivers to working air system.