Assessment and control design for steam vent noise in an oil refinery.
Monazzam MR1, Golmohammadi R, Nourollahi M, Momen Bellah Fard S.
Author information
Abstract
BACKGROUND:
Noise is one of the most important harmful agents in work environment. Noise pollution in oil refinery industries is related to workers' health. This study aimed to determine the overall noise pollution of an oil refinery operation and its frequency analysis to determine the control plan for a vent noise in these industries.
METHODS:
This experimental study performed in control unit of Tehran Oil Refinery in 2008. To determine the noise distributions, environmental noise measurements were carried out by lattice method according to basic information and technical process. The sound pressure level and frequency distribution was measured for each study sources subject separately was performed individually. According to the vent's specification, the measured steam noise characteristics reviewed and compared to the theoretical results of steam noise estimation. Eventually, a double expansion muffler was designed. Data analysis and graphical design were carried out using Excel software.
RESULTS:
The results of environmental noise measurements indicated that the level of sound pressure was above the national permitted level (85 dB (A)). The Mean level of sound pressure of the studied steam jet was 90.3 dB (L). The results of noise frequency analysis for the steam vents showed that the dominant frequency was 4000 Hz. To obtain 17 dB noise reductions, a double chamber aluminum muffler with 500 mm length and 200 mm diameter consisting pipe drilled was designed.
CONCLUSION:
The characteristics of steam vent noise were separated from other sources, a double expansion muffler was designed using a new method based on the level of steam noise, and principle sound frequency, a double expansion muffler was designed.
Assessment and control design for steam vent noise in an oil refinery.Monazzam MR1, Golmohammadi R, Nourollahi M, Momen Bellah Fard S.Author informationAbstractBACKGROUND:Noise is one of the most important harmful agents in work environment. Noise pollution in oil refinery industries is related to workers' health. This study aimed to determine the overall noise pollution of an oil refinery operation and its frequency analysis to determine the control plan for a vent noise in these industries.METHODS:This experimental study performed in control unit of Tehran Oil Refinery in 2008. To determine the noise distributions, environmental noise measurements were carried out by lattice method according to basic information and technical process. The sound pressure level and frequency distribution was measured for each study sources subject separately was performed individually. According to the vent's specification, the measured steam noise characteristics reviewed and compared to the theoretical results of steam noise estimation. Eventually, a double expansion muffler was designed. Data analysis and graphical design were carried out using Excel software.RESULTS:The results of environmental noise measurements indicated that the level of sound pressure was above the national permitted level (85 dB (A)). The Mean level of sound pressure of the studied steam jet was 90.3 dB (L). The results of noise frequency analysis for the steam vents showed that the dominant frequency was 4000 Hz. To obtain 17 dB noise reductions, a double chamber aluminum muffler with 500 mm length and 200 mm diameter consisting pipe drilled was designed.CONCLUSION:The characteristics of steam vent noise were separated from other sources, a double expansion muffler was designed using a new method based on the level of steam noise, and principle sound frequency, a double expansion muffler was designed.
การแปล กรุณารอสักครู่..
ออกแบบ ปล่องควัน เสียงในโรงกลั่นน้ำมัน การประเมินและควบคุม monazzam mr1 golmohammadi
, R , nourollahi M , มัวเบลลาฝาด S .
เขียนข้อมูลบทคัดย่อพื้นหลัง :
รบกวนเป็นหนึ่งในที่สำคัญที่สุดเป็นอันตรายตัวแทนในงานด้านสิ่งแวดล้อม มลพิษทางเสียงในอุตสาหกรรมน้ำมัน โรงกลั่น เกี่ยวข้องกับสุขภาพคนงานการศึกษานี้มีวัตถุประสงค์เพื่อศึกษาโดยรวมมลพิษทางเสียงของโรงกลั่นน้ำมันและการดำเนินการของความถี่การวิเคราะห์เพื่อกำหนดแผนควบคุมเพื่อระบายเสียงในอุตสาหกรรมเหล่านี้
วิธีการ : การวิจัยดำเนินการในชุดของเตหะรานโรงกลั่นน้ำมันใน 2008 เพื่อตรวจสอบเสียงรบกวนการแจกแจงการวัดเสียงรบกวนสิ่งแวดล้อม ได้ดำเนินการโดยวิธีขัดแตะตามข้อมูลพื้นฐานด้านเทคนิคและกระบวนการ เสียงระดับแรงดัน และความถี่ของแต่ละวิชาได้ศึกษาแหล่งแยกแสดงเป็นรายบุคคล ตามสเปคของระบาย ,วัดไอน้ำเสียงลักษณะตรวจทาน และเปรียบเทียบกับผลทางทฤษฎีของการประมาณสัญญาณรบกวน ไอน้ำ ในที่สุด ท่อไอเสียคู่ เป็นการออกแบบ การวิเคราะห์ข้อมูลและการออกแบบกราฟิก ได้ทดลองใช้ Excel ซอฟต์แวร์
ผล : ผลของการวัดเสียงรบกวนสิ่งแวดล้อม พบว่า ระดับความดันเสียงเหนือระดับชาติที่ได้รับอนุญาต ( 85 dB ( A )ค่าเฉลี่ยระดับความดันเสียงของเรียนไอเจ็ทคือ 90.3 dB ( L ) ผลของการวิเคราะห์ความถี่เสียงสำหรับไอน้ำ vents พบว่า ความถี่เด่นคือ 4 , 000 เฮิรตซ์ ได้รับ 17 dB เสียงขึ้น สองห้อง อลูมิเนียม ท่อไอเสียกับ 500 มม. ความยาวและขนาดเส้นผ่าศูนย์กลาง 200 มม. ประกอบด้วยท่อเจาะออกแบบ .
สรุป :ลักษณะเสียงท่อไอน้ำถูกแยกออกจากแหล่ง อื่น ๆ , ผ้าพันคอขยายคู่ถูกออกแบบมาโดยใช้วิธีใหม่บนพื้นฐานของระดับของเสียง ไอน้ำ และหลักเสียงความถี่ ท่อไอเสียคู่ คือ การออกแบบ