1110-1620 FAS Installation
v.3.10 © Lamina System AB 3-2
3.2 Electrical installation
WARNING: Risk of electrical shock. Failure to observe may result in personal injury or death!
Safety during electrical installation
o Make sure the main switch or fuses for the plant line are turned off.
o A neutral connection to the ground is essential for safe operation. Without this connection, there is a risk for electrical shock.
o A disconnected switch with lockout capability must be provided between the power source and the equipment.
o The power supply wire gauge and insulation must be sufficient to meet the power required.
o Only fuses of correct type, voltage rating and current rating should be used.
WARNING: DON’T operate Lamina equipment under the following conditions:
1. Without the covers panels and safety guards properly installed. May result in personal injury or death!
3.2.1 Electric connection, Power inlet
1. Open the electrical enclosure door.
2. Route the power cable into the wire tray in the base of the electrical enclosure.
3. Connect each power cable lead to the appropriate terminal on the electrical board (see fig. 3.2).
Figure 3-2
Standard Electric installation:
Incoming voltage 400 V 3 phases 50/60 Hz
Incoming fuse 16A
EXAMPLE ONLY
(3/N/PE AC wiring shown)