Dear MD,
EEI Lab just informed that the power input testing per Rating label of 32FD545/ 97: 110-240 V (refer attached picture)
Normally they will do testing at +/- 10% (TISI criteria) so they will test at 99V – 264 V but after testing, the highest voltage this model can pass is 245V.
So EEI lab asked Funai to check the design and confirm the voltage at the Rating label.
One choice that EEI lab recommended us is to change the Rating Label detail to 110V-220V so we will pass the test; at +/- 10% is 99V-242V
EEI lab need us decide on this issue and let them know our solution within this Monday 23-Feb-15 whether we will change the rating label or re-design our sample.
Also need Engineering team consider and advise for the solution which is better and safe for us for the range of voltage.
Per EEI plan and timeline; if all test is passed, it will be finished on Friday 27-Feb-15 (They give us a special priority).
If we confirm to change a rating label detail, we need to send them a revised one soonest and we can complete the test per their plan.