To evaluate possible correlation between light intensity and other factors such as RGB or IR values, these parameters should be measured too. In case of any correlation, equipping the inBin with these sensors would reduce the production costs since a sensor providing these data is cheaper than a light intensity integrator. A Maxim integrated MAX44006 is used for these measurements. It stores the intensity of RGB values, IR intensity and the integration of the overall visible light with a sensitivity of 0.001 Lux. Moreover, it measures the temperature with an acceptable accuracy.