Some of the main results are shown in Figures 3 - 6. Focus has been put on showing the RH at the interface between insulation
and the wind barrier, as this typically is the critical area in terms of highest risk for mould growth. The RH at the sensor points 50
mm from wind barrier and at the interface between insulation and vapour barrier are shown in a few of the figures.
The RH are shown at the wind barrier (12 mm fiber board) and vapour retarder (Sd = 2m) for the three various insulation
materials in Figure 3. Outside of the vapour retarder we can see that the glass wool reaches stability very quickly after the test has
started, while the wood fiber insulation has not even reached stability when period 2 is starting. This is probably due to the uniform
high initial moisture content (~10 kg/kg) in the wood fiber insulation