RESULTS: During the intervention, NICUs submitted information on 1916 infants. Of the 242 infections reported, 69% were catheter associated. Compliance with catheter-insertion components was >90% by April 2009. Compliance with components of evidence-based indwelling catheter care reached 80.4% by December 2009. There was a significant reduction in the proportion of infants with at least 1 late-onset infection from a baseline of 18.2% to 14.3%