The results showed that Concentration of total dust before installing the storage system cleaner with mean of 8.8986, and after installing the storage system cleaner with a mean of 0.3513. Storage system can reduce the concentration of total dust in each of the samples up to 96.05%, and respirable dust before installing system with mean of 2.4533, after installing the storage system cleaner. With an average of 0.3711, capable of storing this dust can reduce the concentration of respirable dust in each of the samples up to 95.83%. And from the statistical test using Paired sample t-test found that the average amount of the total dust concentration (Total Dust) and dust (Respirable Dust) are small. Before and after the installation of the system in different catchment dust not significant. Storage system was designed can reduce the concentration of dust in the atmosphere that cause risks to the health of workers effectively. And can be applied to the process trimming of sandstone sculptures cast in community Chok Chai district of Nakhon Ratchasima.