Gasoline or Diesel-Powered Materials Handling Equipment.
8.32.1. Equip with a standard muffler and air cleaner.
8.32.2. Ensure gas caps are in place.
8.32.3. If necessary, install a deflector plate to prevent overflow from the fuel tank from reaching motor or exhaust pipe.
8.32.4. On gravity feed fuel systems or on pump systems that can be siphoned, install an emergency shutoff valve at fuel tank or in the feed line.
8.32.5. Protect fuel lines from rupture due to vibration.
8.32.6. Securely fasten electrical connections to prevent accidental disconnection that might result in sparks or fire.
8.32.7. Do not use equipment in areas classified as hazardous locations