[Alarm Input Channel No.] Select the alarm input channel.
[Enable] Select “Enable” to control the ON and OFF of alarm input.
[Type] Two selection modes: Normal Open and Normal Close.
[Copy] Copy the configuration to other channels.
[Processing] Click “Processing” and enter into the setting interface of alarm processing, the interface is shown in Figure 4-16. [Arming Time period] The menu will display the arming time, entering into the edit plan can configure the arming time of each day.
[Linkage Set] Click “Enable” to start the linkage of [Recording Channel Linkage], [PTZ Linkage], [Polling] and [Capture], and select the linkage channels.
[Processing] Click “Enable” to start the [Alarm Output], [Screen Prompt], [Send Email] and [Beep].
Alarm cancel delay time can be set as 10-300s.