Tocopherols
Racemic tocol was used as IS, being incorporated in the extraction procedure previously described by the authors (Guimarães
et al., 2013a). The HPLC equipment was described in Section
2.3.1., but with a fluorescence detector (FP-2020; Jasco, Easton,
MD, USA) programmed for excitation at 290 nm and emission at
330 nm. The chromatographic separation conditions were as follows: a Polyamide II (5 m, 250 mm × 4.6 mm i.d.) normal- phase
column (YMC Waters, Dinslaken, Germany) at 35 ◦C; a mixture of nhexane and ethyl acetate (70:30, v/v) as mobile phase, at 1 mL/min.
The identification was performed by comparison with standards,
and the quantification was based on calibration curves obtained
from commercial standards using the IS method. The results were
expressed in mg per 100 g of dry weight.