Due to the difficulties in measuring the input power into the turbine at a constant speed, a series of
acceleration/ deceleration tests were conducted to estimate the level of power losses in the turbogenerator.
Power losses in the turbogenerator, may be calculated by measuring the deceleration of the machine
through its operating speed, with no load or input power to the turbine, since they are the only cause of
the decelerating force