The duct and check valve assembly hinge is spring loaded to hold the swing check valve slightly open when air conditioning is off. When air conditioning is on the pressure in the distribution ducts is enough to overcome the spring load and cause the check valve to close. Before installation of a duct and check valve assembly the check valve should be checked and the hinge adjusted, if required, to obtain the open or closed position