The design process for brushless permanent magnet DC motors with segment rectangular wires was performed in order to find the proper slot opening dimension and slot-pole combinations necessary to achieve high power density per volume with similar efficiency.
The torque analysis shows that the cogging torque depends mainly on the length of the slot opening, and that efficiency and output power are decreased by the magnetic flux leakage of teeth in the case of motors with a closed slot opening.