Conductivity measurements of
free-standing CCG films prepared by vacuum filtration were carried out on a Jandel RM3 Test Unit
using a four-point-probe head with a pin-distance of about 1 mm.Mechanical tensile tests were
conducted with a Q800 Dynamic Mechanical Analyzer (TA Instruments).