quenching operation according
to the Jominy test
was applied considering three conditions. 1. Standard water pressure at
65 mmWC, ( 18 C), 2. Water pressure at 32.5 mmWC, ( 18 C),
3. Water pressure at 22 mmWC (2,5 lt/m flow) water and air mixture (0.40 bars) ( 18 C) (This condition is equivalent to the standard Jominy water pressure at 65 mmWC.) Under these conditions,
after being heated up to the austenite temperature, the samples
were subjected to the hardenability process in the test setup as
shown in