The selection of preheat temperatures to prevent high-hardness heat-affected zones should be guided by experience as well
as by calculation whenever possible. The optimum preheat temperature is the lowest temperature that maintains the cooling rate somewhat below the erit-ical cooling rate, thus allowing for a margin of safety.