7. If there are problems with the results of a point, align the cursor with that point and press [OMIT]. “OMIT” is displayed to the right of the point. Repeat for all results that include problems.
8. Press [RE CALC] to perform calculation again without the point designated in step 7 The result is displayed.
If there are no problems with the result, go to step
9.
If problems with the result occur again, perform the resection measurement from step 4.
• Press [RE_OBS] to measure the point designated in step 7.
If no points are designated in step 7, all the points or only the final point can be observed again.
• Press [ADD] in the second page when there is a known point that has not been observed or when a new known point is added.
9. Press [OK] to finish resection measurement and return to . Only Z (elevation) of the instrument station coordinate is set. N and E values are not overwritten.