Recommendations:
· For more beneficial to developing incubator, the
temperature and humidity control must be
produced by the proper control. The temperature
varies less than a total of 1°C. The tuning system
can be improved to be an automatic tuning system
instead to by the installation of timing relay
· To develop a mathematical model for predicting
the temperature in a cabinet, the condition of air
inside cabinet considered to forced air. Moreover,
effect of egg size and metabolic heat production of
embryo of egg is needed to consider
· The incubator must be located in the area, which is
kept at 25-27°C and is well ventilated