For the desorption test, a set of seven conical flasks containing
1000 mg treated oil palm fibre was filled with 100mL
of 100 mg/L Cr (VI) solution and adjusted to the optimum pH
for adsorption. The flasks were agitated using an orbital shaker
maintained at 350 rpm for a contact time of 2 h. The liquid portions
were then decanted and analysed for Cr (VI) concentration,
whereas the solids were washed five to six times with distilled
water to remove traces of Cr (VI) not adsorbed by the adsorbent.
The adsorbent was then dried in an oven at 105 ◦C for 24 h
and the actual mass of adsorbent left from each adsorption test
was measured using an analytical balance. The adsorbents were
then mixed with 100mL of 1N H2SO4, 1NHNO3, 1N HCl, 1N
NaOH, 1N Na2CO3, 1N NaHCO3 and 1N NaCl solutions and
agitated as described before in the adsorption test. The concentrations
of Cr (VI) released into the solutions were analysed and
the desorption efficiency was calculated based on mass balance.
สำหรับการทดสอบการคายออกชุดของเจ็ดขวดรูปกรวยที่มี
1000 น้ำมันมิลลิกรัมเส้นใยปาล์มได้รับการรักษาก็เต็มไปด้วย 100ml
จาก 100 mg / l โซลูชั่น CR (vi) และปรับให้
pH ที่เหมาะสมในการดูดซับ ขวดถูกปั่นป่วนโดยใช้เครื่องปั่นโคจร
ไว้ที่ 350 รอบต่อนาทีเป็นเวลาติดต่อจาก 2 ชั่วโมง ส่วนของเหลว
ถูก decanted แล้วและวิเคราะห์ความเข้มข้นของโครเมียม (VI),
ในขณะที่ปริมาณของแข็งที่ถูกล้าง 5-6 ครั้งด้วยน้ำ
กลั่นเพื่อลบร่องรอยของ CR (vi) ไม่ดูดซับโดยตัวดูดซับ.
ตัวดูดซับแห้งแล้วในเตาอบที่อุณหภูมิ 105 ◦ C เป็นเวลา 24 ชั่วโมง
และมวลที่แท้จริงของตัวดูดซับ ที่เหลือจากแต่ละ
ทดสอบการดูดซับถูกวัดโดยใช้เครื่องชั่งวิเคราะห์แบบ ตัวดูดซับผสม
แล้วกับ 100ml ของ 1n H2SO4, 1nhno3, 1N HCL, 1n
NaOH, 1n Na2CO3,1n 1n NaHCO3 และโซเดียมคลอไรด์และโซลูชั่น
ตื่นเต้นก่อนที่จะอธิบายว่าในการทดสอบการดูดซับ
ความเข้มข้นของ CR (vi) ปล่อยให้เข้ามาแก้ปัญหาที่ถูกนำมาวิเคราะห์และ
ประสิทธิภาพคายที่คำนวณบนพื้นฐานของความสมดุล
การแปล กรุณารอสักครู่..