Heat exchanger Class C and B designs are more compact and economical than Class R designs. The
users must select the design/fabrication code designation for their individual application. The standards do
not include recommendations for the selection of a particular class. Many chemical plants select the most
severe class, Class R, because they prefer a more robust construction.