A hydration-resistant, burned magnesite brick is used to construct the subhearth with the overlying hearth made from either pitchimpregnated, burned magnesite brick or a dry, vibratable, Austrian-type magnesite. Water-cooled panels now also compose the bulk of the EAF roofwith high-alumina castableswith orwithout spinel additions in the delta section.