1110-1620 FAS Installation
v.3.10 © Lamina System AB 3-4
3.4 Glue system installation
NOTE: It is important to use glue intended for the material in production and suitable for the glue unit and nozzles.
NOTE: The glue consumption can vary depending on production speed, properties of the glue and/or of the material in production.
Check all hoses and connection cables are connected and secured on the glue pump and on
the glue system. Make sure no hoses or cables were damaged during the transport.
Connect the glue pump (1) to the glue barrel with the glue inflow hose (5).
Connect the return hoses. Return hose from glue nozzles (3), return hose from glue rollers (4).
Pump speed is regulated by the air valve (2), normal pace should be around 1 to 2 seconds between paces.
Figure 3-4
The glue amount on glue rollers are regulated with a photocell placed on the glue roller cover (Refer to chapter 4.2.2).
The glue pump are turned on or off on the on the manual running page on display (Refer to chapter 5.1) or by closing air valve (2).
2
6
4
5
1
3