The electric circuit’s load resistance is set to approximately 20 U since it was shown in Lesage and Pagé-Potvin [24] that for the present generator, an optimal electrical load maximizing power output is within the range of 15.8 Ohms 15% which is near electrical impedance matching. This was shown to be true for a wide range of thermal input parameters including a variation in temperature and in flow rates. It was also shown in their study that the descent from peak power for electrical loads greater than optimal is more gradual than that for electrical loads less than optimal. This implies that an error in setting an electrical load inferior to optimal is more costly than an error in setting the electrical load greater than optimal. For this reason a slightly greater than optimal electrical load is imposed on the present work’s circuit, as illustrated