. It was pointed out earlier that the common-mode voltage appearing at the amplifier inputs has essentially the same value as at the signal ground point. Thus, by connecting the guard and cable shields to the signal ground point, the signal cable, amplifier-guard shield circuit becomes driven to that common-mode voltage as well.