8
the description and unique identification of the equipment manufacturer, type, serial number, etc.;
the date on which the metrological confirmation was completed;
the result of the metrological confirmation;
the assigned interval for metrological confirmation;
identification of the metrological confirmation procedure (see 6.2.1);
the designated maximum permissible error(s);
the relevant environmental conditions and a statement about any corrections necessa~
the uncertainties involved in calibrating the equipment;
details of any maintenance, such as adjustment, repairs or modifications carried out;
any limitations of use;
identification of the person(s) performing the metrological confirmation;
identification of the person(s) responsible for the correctness of the recorded information;
unique identification (such as serial numbers) of any calibration certificates and reports, and other
relevant documents;
evidence of the traceability of the calibration results;
the metrological requirements for the intended use;
the calibration results obtained after and, where required, before any adjustment, modification or