A manufacturer develops a new type of flow control valve. Before it can be advertised and sold, its loss coefficient must be determined. The valve is installed in a 6-in. pipe and 2 ft3/s of water flows through it. The pressure drop is measured with a manometer whose fluid has a specific gravity of 1.3. The manometer deflection is 7.5 in. Determine the loss coefficient for the valve.