In the C-scan image, the reflected energy of the signal obtained at successive inspected points performing an area is represented as a color at each point of the inspected area. C-scan images represent horizontal cuts of the part under test as it can be integrated only the energy coming from a specific depth range. For this reason, in an image of this type color changes where a crack is located as much more energy is reflected there.