For special bends such as short radius bends, Hammerteck,
Gamma, pocket-T's, etc., increase the value of 40 to a higher
number. For example, for a typical conveying system with about
5 bends increase the calculated pressure drop value by 10%.
For 10 bends increase it by 20%. These numbers are based on
lab tests or plant data.