1. Edge wave from mother coil.
Is this edge wave continuing from outer side to inner side?
If this edge wave is occurring at the point where the squareness was measured
It may influence the measured result.
Please make clear in the report.
2.Cutter mark
This problem is not concerned to the test at THAPT.
Please delete.
3.Burr is high
THAPT should clear this result and report method to control burr to us.
4.Width of mother coil
This problem is not concerned to the test at THAPT.
Please delete.
5.Lengh in THAPT
Seeing the table of th cutting result, length in THAPT may be out of spec
THAPT should clear this result and report method to control burr to us.
6.Squareness
Squareness is seen that it has deviation in the table cutting result.
Squareness is influenced by the variation of the width of mother coil or edge wave.
7.Conclusion
All report should have the conclusion.
I think this trial in THAPT is not success.
We should make next trial plan.
But before making next trial plan, we need let THAPT report about Burr and length deviation to us.