Study Interfacial Contact Resistance (ICR) by through-plane
technique. Prepare sample followed by 1 cm. * 2 cm. * 0.2 cm.
And then, give current in range of 0.1 – 0.5 Ampair with different
force (100, 120, 140, 160 and 180 lbf.in) and measure voltage.
Plot graph between voltage and current to calculate resistivity
from slope of graph. And then, calculate Interfacial Contact
Resistance (ICR) of sample. The results were shown in “Fig. 5”.