4. Mount the 260-5865 Toggle Switch in a convenient location in the cab. Refer to Illustration 38. Illustration 38 is
not to scale. Place the 293-4950 Film near the switch.
5. Run two lengths of 5P-9075 Electrical Wire between the splices and the toggle switch. Protect the wire and tiewrap
the wire.
6. On the splice end of the wire, strip the insulation from each end of the wire. Crimp a 8T-8729 Connector Pin to
each bare wire. Insert the connectors into the open ends of the splices.
7. On the switch end of the wire, strip the insulation from each end of the wire. Crimp a 8T-8730 Connector
Socket to each bare wire. Insert the two sockets into location A and location B of a 155-2267 Connector Plug As
. Insert a 155-2276 Plug Lock Wedge in order to lock the sockets in place.
8. Connect the 155-2267 Connector Plug As to the 3E-3370 Connector Receptacle As on the 260-5865 Toggle
Switch .
9. Place the main disconnect switch in the ON position.
10. Verify that no power is applied to the PL522/523 ECM.
11. Place the PL522/523 disconnect switch into the ON position. Verify that power is applied to the PL522/523
ECM.