The two-phase closed thermosyphon system is technically advantageous because of its higher thermal efficiency
achievable with indirect fluid circulation. It presents larger
climate adaptability than the single-phase system. Taking
no account of the less favorable investment and cost payback period, it is an attractive alternative for its capability
to generate more hot water per collector unit. In particular,
the potential of adopting building integrated design is an
additional asset.