Vertical forces are applied through a metal platen resting on the top serrated plate. Horizontal
forces are applied through a motor for displacement control or by weights through a pulley system for
load control. Most shear box tests are conducted using displacement control because we can get both
the peak shear force and the critical shear force. In load control tests, you cannot get data beyond the
maximum or peak shear force.