2.4. Water permeability
A steady flow method was applied to test the permeability of the concrete. The
coefficient of the water permeability was determined by measuring the amount of
water passing through the specimen and calculated using Darcy’s Law and the
equation of continuity [6],
Kf ¼ qLgQ
PA ð1Þ
where Kf is the coefficient of water permeability of the specimen (m/s), q the density
of water (kg/m3
), L the length of the specimen (m), g the acceleration due to gravity
(m/s2
), Q the net flow rate (m3
/s), A the cross-sectional area of the specimen (m2
),
and P is the water pressure [(kg m s2
)/(m2
)].
The samples were prepared by sawing 40 mm thick slice from the middle of the
cylinder before testing the water permeability two days. After drying in the laboratory
for 24 h, the concrete slices were cast in a 25 mm thick layer of non-shrinkage
epoxy resin to prevent water leakage. The epoxy resin was allowed to harden and
dry for another 24 h. The specimens were then installed in the housing cells, as
shown in Fig. 1a, upon which a water pressure of 0.5 MPa was applied. This pressure
was also used by both Chan and Wu [7] and Chindaprasirt et al. [8]. The time and
the amount of water that passed through each of the specimens were monitored
until a constant flow rate was obtained. The water permeability test apparatus is
shown in Fig. 1b.
2.4. Water permeabilityA steady flow method was applied to test the permeability of the concrete. Thecoefficient of the water permeability was determined by measuring the amount ofwater passing through the specimen and calculated using Darcy’s Law and theequation of continuity [6],Kf ¼ qLgQPA ð1Þwhere Kf is the coefficient of water permeability of the specimen (m/s), q the densityof water (kg/m3), L the length of the specimen (m), g the acceleration due to gravity(m/s2), Q the net flow rate (m3/s), A the cross-sectional area of the specimen (m2),and P is the water pressure [(kg m s2)/(m2)].The samples were prepared by sawing 40 mm thick slice from the middle of thecylinder before testing the water permeability two days. After drying in the laboratoryfor 24 h, the concrete slices were cast in a 25 mm thick layer of non-shrinkageepoxy resin to prevent water leakage. The epoxy resin was allowed to harden anddry for another 24 h. The specimens were then installed in the housing cells, asshown in Fig. 1a, upon which a water pressure of 0.5 MPa was applied. This pressurewas also used by both Chan and Wu [7] and Chindaprasirt et al. [8]. The time andthe amount of water that passed through each of the specimens were monitoreduntil a constant flow rate was obtained. The water permeability test apparatus isshown in Fig. 1b.
การแปล กรุณารอสักครู่..

2.4 การซึมผ่านของน้ำ
วิธีการไหลคงถูกนำมาใช้ในการทดสอบการซึมผ่านของคอนกรีต
ค่าสัมประสิทธิ์ของการซึมผ่านของน้ำที่ถูกกำหนดโดยการวัดปริมาณของ
น้ำผ่านชิ้นงานและการคำนวณโดยใช้กฎของดาร์ซีและ
สมการของความต่อเนื่อง [6],
Kf ¼ qLgQ
PA ð1Þ
ที่ Kf คือค่าสัมประสิทธิ์ของการซึมผ่านของน้ำของชิ้นงาน (ม. / s), คิวความหนาแน่น
ของน้ำ (kg / m3
), L ความยาวของชิ้นงาน (m) กรัมเร่งเนื่องจากแรงโน้มถ่วง
(m / s2
) Q อัตราการไหลสุทธิ (m3
/ s), พื้นที่หน้าตัดของชิ้นงาน (m2
)
และ P คือความดันน้ำ [(กกม. s2
) / (m2
)].
ตัวอย่างที่ถูกจัดทำขึ้นโดยเลื่อย 40 มิลลิเมตรหนาชิ้นจากตรงกลางของ
ถังก่อนการทดสอบการซึมผ่านของน้ำ สองวัน หลังจากการอบแห้งในห้องปฏิบัติการ
เป็นเวลา 24 ชั่วโมง, ชิ้นคอนกรีตหล่อใน 25 มมหนาไม่หดตัว
อีพอกซีเรซินเพื่อป้องกันการรั่วซึมของน้ำ อีพอกซีเรซินได้รับอนุญาตที่จะแข็งและ
แห้งอีก 24 ชั่วโมง ตัวอย่างที่มีการติดตั้งแล้วในเซลล์ที่อยู่อาศัยในขณะที่
แสดงในรูป 1a ตามที่แรงดันน้ำ 0.5 MPa ถูกนำมาใช้ ความดันนี้
ยังถูกใช้โดยทั้งหลงและวู [7] และจินดา et al, [8] เวลาและ
ปริมาณของน้ำที่ผ่านแต่ละตัวอย่างถูกตรวจสอบ
จนกว่าจะมีอัตราการไหลอย่างต่อเนื่องที่ได้รับ การซึมผ่านของน้ำเครื่องทดสอบจะ
แสดงในรูป 1b
การแปล กรุณารอสักครู่..