New: Powder contact
The segment with the longest powder transfer travel determines the powder transfer. By programming the value 100 other pun-ches will come into contact with the powder at the same time as the leading punch. By programming the value 0 the punch will already be moved to powder transfer position before the powder contact. Values between 0 and 100 continuously allow for positi-ons between the two extreme positions mentioned above. The position of the leading punch remains unchanged due to the IPG®.
Adjustment of upper and lower punch
This value has to be keyed in if the positive stops of the individual levels are adjusted. If these adjustments are not considered, the filling height will change and the starting points of the individual platens will be triggered at the wrong time.
Lower ram offset
If the options Additional level 2 and Platen on lower ram have
been activated, the offset of this level towards the upper edge of
the die in pressing position (value dxv) has to be entered in the representation of phase 3 (see chapter "1.5 Representation of phase 3" on page 20). The measurement is taken from