The divergent X-ray beam from the X-ray source, which was positioned at
an input focal distance F1 away from the input of the PFXRL, was
focused by the PFXRL into an output focal spot at an output focal
distance F2 away from the output of the PFXRL. The PPXRHL was
placed confocally at an input focal distance F3 away from the
output focal spot of the PFXRL The X-ray source used was a Mo rotating-anode X-ray generator whose spot size is 300300 μm2. The detector system is composed of an XFlash Detector 2001 RÖNTEC and a RÖNTEC MAX
Spectrometer.The crystal thickness of the detector is 0.3mm. The
peak-to-background-ratio is better than 400:1 for MnKα radiation
at 5.89 keV.The maximum count rate of the detector system is
4105 counts/s The energy resolution of this detector system is
142eVat5.9keV,and the entrance size of the detector is 5mm2