Dear Jirayuth S san
I'm sorry. Previously was also thought to have tested.
Therefore, it was lack of information.
1)Humidity examination is necessary.
2) Please send the specification sheet or drawing.
Because different Label specification,
NDS will be newly numbered, will issue specifications.
1)-----
A)Safekeeping examination (Humidity examination)
40+-2 [℃], humidity 90-95 [%], 48[H],No packing
.
normal temperature
a)Power ON
b)checks the Projector operation
c)Power OFF
d)48H test
e)after 1[H] leaving.
But check the operation after leaving until dew condensation disappears
f)Power ON
g)checks the Projector operation
h)Power OFF
----
Best Regards.
S.Murakami