The transmission X-ray tube is located inside ตู้ป้องกันรังสี above the แผ่นวางตัวอย่าง and opposite the detector.
The electron beam generator and transmission anode which are required to generate the X-rays are located inside the X-ray tube (ภาพที่ 17/1) .
The X-ray beams exit the X-ray tube through the target (beam exit window) (ภาพที่ 17/2).
The X-ray radiation emitted pervades the entire half space beneath the target level.
The detector (ภาพที่ 18/1) is situated in ตู้ป้องกันรังสี be-neath the แผ่นวางตัวอย่าง opposite the X-ray tube.
The X-rays pene-trate the sample and hit the detector.
The live image information is transmitted to the diagnostic imaging software in real time.
With the ovhm|module (oblique view at highest magnification) you can change the detector angle to achieve a vertical beam path.
This is partic-ularly useful for examining solder joints that require inspection from an oblique angle at the highest possible magnification.
This is made possible by sliding the detector on curved slide tracks (ภาพที่ 18/2).
The high-voltage generator supplies the high voltage and auxiliary voltages required for X-ray generation.
The high-voltage generator is located on the lower right behind the right-hand service doors.
The แผ่นวางตัวอย่าง moves the sample in a horizontal (x, y) and
vertical (z) direction between the X-ray tube and detector.
The แผ่นวางตัวอย่าง features an integrated turntable (ภาพที่ 20/2).
A CFK plate can be placed in the opening of the rotation table.
As an option, the แผ่นวางตัวอย่าง can be fitted with a PCB holder (ภาพที่ 20/1) or rotation/tilt axis.
The sample is manually clamped in the PCB holder, placed on a CFK plate or clamped in rotation/tilt axis.