The magnetic inputs include maximum magnetic flux density
Bmax and permeability μ. The mechanical inputs include the
footprint radius Rc and inductor height Hc . The uniformity
factor α is swept and all design variables are calculated until
the required inductance Lo and dc resistance Ro are met. The
procedure is described later with the flowchart in Fig. 5.