After studying the corrosion and wear of balls by SEM/EDX,
operating parameters influencing the wear rate of steel balls were
quantitatively evaluated using experimental design technique,
response surface methodology (RSM). Tables 3 and 4 show selected
parameters levels and wear rate calculated under experimental
different conditions based on response surface model by a Doptimal
design of experiment, respectively.