Incinerator infected by hydrogen gas spend for burning wast cotton gauze and using hydrogen gas as a fuel to burn. Incinerator infected by hydrogen gas consists of three main parts is the DC power supply ,The production of hydrogen And the incinerator infection. The distilled water used is 2 liters and mixed with sodium bicarbonate (NaHCO3) of 300 grams. The trial will test burning infectious waste volume 1 Kg . Measurement of electricity in produce hydrogen and timer burning waste infections .Found that i can take the hydrogen from the electrolysis process used as fuel in incineration infected with volume 1 kg of hydrogen electric current 15 amps and incinerators infected with hydrogen as a clean energy When the ignition is odorless and colorless
Compared to incinerators infectious medical waste At present, we can see that Incinerator, infection with hydrogen gas will cost lower than medical incinerator in the present.