A proprietary Zeuch method injection analyzer was developed.
A comparison with a Bosch-pipe evidenced a better accuracy in the injection start and end detection.
A criterion to determine the actual injection start was defined.
The injection rate in reduced dwell-time operation was investigated.
The reduced dwell-time operation is possible approaching the boot-shaped injection.